– FSP Champ Rack Series is the high density version of double-conversion online UPS with a output power factor 0.9.
– It’s designed in small cabinet with microprocessor controller.
– It also has USB and RS-232 communication ports as standard, with a built-in intelligent slot for additional adapters, protocol converters and relate contact cards.

Features
– Capacity: 10000VA/9000W
– Power Factor (PF): 0.9
– Wave Form: Sine wave
– Battery: 16pcs CSB 9Ah battery inside
– Battery Extension: Yes
– Intelligent Slot: SNMP, AS400, RS485-Modbus
– Built-in MBS: Yes
– Network Ports: USB, RS-232, EPO
– Box contents: UPS, user manual, software CD, USB cable

Specifications
– Model: Champ TW 10K
– Capacity: 10000 VA / 9000W
– Input Voltage Range: 110-300 VAC (50% load), 176-300VAC (100% load)
– Input Frequency: 46Hz ~ 54Hz or 56Hz ~ 64Hz
– Power Factor: ? 0.99 @ Nominal Voltage (100% load)
– Output Voltage: 208/220/230/240 VAC
– Output Frequency Range: 46Hz ~ 54Hz or 56Hz ~ 64Hz
– Current Crest Ratio: 3:1
– Harmonic Distortion:
• ? 3 % THD (Linear Load)
• ? 5 % THD (Non-linear Load)
– Output Transfer Time (Typical)
• Zero (AC to DC)
• Zero (Inverter to Bypass)
– Output Waveform (Batt. Mode): Pure Sinewave
– Battery Type & Number: No internal battery
– Backup Time: Up to 6mins @ full load
– Typical Recharge Time (up to 90% capacity): 4 hours
– Indicators / AC Mode: ?
– Indicators / Battery Mode: ?
– Indicators / Battery level: ?
– Indicators / Load level: ?
– Indicators / Bypass mode: ?
– Indicators / Fault: ?
– Alarm / Battery Mode: Sounding every 4 seconds
– Alarm / Low Battery: Sounding every second (Batt. Mode)
– Alarm / Overload: Sounding twice per second
– Alarm / Fault: Continuously sounding
– Physical Dimension (mm): 442 x 190 x 318 (DxWxH)
– UPS Net Weight (kg): Long run time Model: 16
– Operating Environment / Humidity: 20-90 % RH @ 0- 40°C (non-condensing)
– Operating Environment / Noise Level: Less than 50dB @ 1 Meter
– Management / Optional USB / RS-232 Port: Supports Windows 98/XP/2000/Vista/7/8/10, Windows Server 2000/2003/2008/2012/2016, Linux, and MAC
– Optional SNMP: Power management from SNMP manager and web browser

 

Ukoliko proizvod nije dostupan, onda je u dolasku i sve možemo nabaviti. Samo nam pošaljite upit.

Zašto Alpha-M?

Nudimo Vam usluge održavanja računala i računalnih mreža, pomoć pri izradi sigurnosnih kopija podataka i načine izrade sigurnosnih kopija. Rješavamo probleme s računalima nastale utjecajem virusa i zlonamjernih programa.

Otkrivamo Vam kako uz minimalne investicije učiniti postojeću informatičku opremu da radi brže i bolje. Najveći naglasak dajemo na zaštitu podataka i sigurnost istih.

Pomažemo pri odabiru najpovoljnije i optimalne opreme koja bi omogućila brže i efikasnije izvođenje svakodnevnih zadataka na računalima. Saznajte kako uštedjeti u svakodnevnom poslovanju i smanjiti troškove.

Dajemo savjete za legalizaciju programa…